K-2000-DV
K-2000-DV
A
A
Multi-Input Voice
Dialer/Announcer
June 11, 2004
Power: 120V AC/12V DC 500 mA, UL listed adapter provided
Dimensions: 211mm x 160mm x 46mm (8.3” x 6.3” x 1.8”)
Shipping Weight: 1.02 Kg (2.25 lbs)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95% non-
condensing humidity
Talk Battery: 12V DC
Touch Tone Dialing: 120 ms on/off, 50 ms on/off
CPC Detection Time: 320 ms minimum
Message Record Time: 8 minutes
Sampling Rate: 64 K (equivalent)
Input Detection Time: 80 ms with Qualifier Timer set to 0
Resolution Qualifier/Resume Timers: 1 second, with 18 hours
maximum capacity
Connections: (1) RJ11 jack for telco connection, (1) 3.5mm jack
for 600-ohm audio output, (1) 9 pin RS-232 for connection to PC,
(1) 12 position screw terminal block for inputs
Voice Alarm Dialing or Store Caster
Announcements from up to Eight Inputs
P
P
r
r
a
a
c
c
t
t
i
i
c
c
e
e
T
T
E
E
L
L
E
E
C
C
O
O
M
M
S
S
O
O
L
L
U
U
T
T
I
I
O
O
N
N
S
S
F
F
O
O
R
R
T
T
H
H
E
E
2
2
1
1
S
S
T
T
C
C
E
E
N
N
T
T
U
U
R
R
Y
Y
TECHNICAL
TECHNICAL
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
• Non-volatile memory (no batteries required)
• Stores up to eight 32-digit numbers (sixty four
32-digit numbers total)
• 8 minutes of record time (1 minute per input)
• Programmable message repeat counter
• Programmable lap counter
• Eight inputs programmable as normally open or
normally closed and enabled or disabled
• Programmable ring delay for remote programming
and alarm polling
• Programmable qualifier timer for each input
(time for an event to be qualified as an alarm)
• Programmable resume timer for each input
(time following reset for input to become
active again)
• Call progress detection
• Programmable ringback limit for call progress
• Remote security and access codes
• Store caster mode
• Local or remote programming and recording
• RS-232 port for programming via a PC
• Compatible with the RC-2A and RC-3 remote
DTMF controllers
Viking’s K-2000-DVA is a fully programmable multi-input, multi-
number auto dialer and digital announcer, designed for emer-
gency and non-emergency message notification. The K-2000-
DVA has eight dry contact inputs, each of which can dial up to
eight 32-digit phone numbers and play a message up to 1
minute in length specific to that input.
Messages can be recorded locally or remotely with a total mes-
sage time for all 8 inputs of eight minutes. When configured as
an alarm dialer, the K-2000-DVA has call progress detection
capability with normal and fast busy, call pickup, CPC and ring-no-answer detection.
The K-2000-DVA can also be set up as a store caster (no dialing), for on-site promotional or
assistance announcements.
Programming can be done with a
Touch Tone phone or using a PC with
a serial port connection and software
available on the Viking website:
http://www.vikingelectronics.com.
Alarm Dialer
• Security/burglar/fire alarm notification
• System alarm or equipment malfunction notification
• Environmental warning notification
Automatic telephone messaging paging
Store Caster
• Provide assistance or promotional announce-
ments in department stores, grocery stores, hard-
ware stores, gas stations, etc. “Customer assis-
tance needed in aisle 13...”
A
A
p
p
p
p
l
l
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
P
P
h
h
o
o
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
8
8
8
8
6
6
1
1
h
h
t
t
t
t
p
p
:
:
/
/
/
/
w
w
w
w
w
w
.
.
v
v
i
i
k
k
i
i
n
n
g
g
e
e
l
l
e
e
c
c
t
t
r
r
o
o
n
n
i
i
c
c
s
s
.
.
c
c
o
o
m
m
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - TECHNICAL

K-2000-DVK-2000-DVAAMulti-Input VoiceDialer/AnnouncerJune 11, 2004Power: 120V AC/12V DC 500 mA, UL listed adapter providedDimensions: 211mm x 160mm x

Page 2

IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, PLEASE CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666Our Technical Support Department is available f

Page 3 - A. Alarm Dialer

C.O. Line or AnalogPABX/KSU Station(Programming switch = NORM)* Personal Computeror ModemVIKING12V DCAdapterIncluded120V ACVIKING©MODEL K-2000-DVAVIKI

Page 4 - B. Store Caster

PPrrooggrraammmmiinnggA. Entering the Programming Mode1. LocalStep 1. Move the PROG/NORM switch to PROG and plug an analog phone in to the TELCO jack

Page 5

B. Quick Programming FeaturesEntering phone numbers for each input ...To play message

Page 6

O. Programming the Phone NumbersTo program one of the eight phone numbers for each alarm input enter: 0 - 32 + # + XY (where X is the input number(1 -

Page 7 - B. Store Caster Mode

The K-2000-DVA constantly monitors all eight alarm inputs to see if any of them leaves their normal state (N/Obecomes closed or N/C becomes open) for

Page 8 - ZF301040 Rev C

The PA-2A provides loud ringing and paging to electronic key systems, 1A2 Keysystems, PABX’s as well as No-KSU phones and multiline phones.Paging is a