Feature # : Description:
1 Beacon/Strobe (factory default)
2 Strobe Only
3 Beacon Only
4 Strobe Brightness 1-6 (factory default = 6/Brightest setting)
5 Beacon Brightness 1-6 (factory default = 6/Brightest setting)
6 Single Flash Strobe (factory default)
7 Double Flash Strobe
8 Quad Flash Strobe
9 Flicker Flash Strobe
10 Reset to Factory Default Settings
C. Programming Features List
D. Strobe Flash Patterns
Operation
When the control module detects an incoming ring signal, it activates a set of normally open or normally closed
contacts and turns on the 12VDC output for activating the provided strobe light. With the Ring Cadence mode off
(DIP switch 2 OFF), the relay will activate and the strobe light will flash only during ringing. With the Ring Cadence
mode ON (DIP switch 2 ON), the relay will remain activated and the strobe light will remain flashing between rings.
A. Ring Indication (DIP Switch 1 ON)
When the control module detects an off-hook condition (loop current) on the brown and gray wires, it activates a
set of normally open or normally closed contacts and turns on the 12VDC output for activating the provided strobe
light. The relay contacts will remain activated and the blue strobe light will flash during the off-hook condition and
will stop flashing approximately 3 seconds after the phone/terminal device on the brown and gray wires is back
on-hook.
B. Off-Hook Indication (DIP Switch 3 ON)