Wire
The Spectra i.Net
®
system uses Cat 5e/5E
and RJ45 connectors for audio and data
connections.
Helpful Hint:
Use different colors for your Cat 5e/5E cables to
easily identify audio vs. data cable runs.
Audio Cable (cable from OP to speakers
and speaker to speaker)
The pin out on the RJ45 is straight.
The connectors for the audio cables are non-
plated.
Data Cable (cable from i.Lon to MPI to
OP1 and OP to OP)
The pin out on the RJ45 is straight
.
The connectors for the data cable are plated.
TIA/EIA – 568-B wiring is standard
Pin 1 and Pin 2 are the network wires
(orange wires)
Pin 3 and Pin 6 are for initialization (green
wires)
Pin 4 and Pin 5 are for paging (blue wires)
Pin 7 and Pin 8 are for music (brown wires)
NOTE: Lencore recommends “long throat” connector types for integrity and ease of
use.